 68 pin hi-density D-SUB female connector at the controller & devices | Pin
| Name
| Dir
| Description |
1-16 | GND |  | Ground |
17 | TERMPWR |  | Termination Power |
18 | TERMPWR |  | Termination Power |
19 | res |  | reserved |
20-34 | GND |  | Ground |
35 | DB12 |  | Data Bus 12 |
36 | DB13 |  | Data Bus 13 |
37 | DB14 |  | Data Bus 14 |
38 | DB15 |  | Data Bus 15 |
39 | DPB1 |  | Data Parity (odd Parity) |
40 | DB0 |  | Data Bus 0 |
41 | DB1 |  | Data Bus 1 |
42 | DB2 |  | Data Bus 2 |
43 | DB3 |  | Data Bus 3 |
44 | DB4 |  | Data Bus 4 |
45 | DB5 |  | Data Bus 5 |
46 | DB6 |  | Data Bus 6 |
47 | DB7 |  | Data Bus 7 |
48 | DPB |  | Data Parity (odd Parity) |
49 | GND |  | Ground |
50 | GND |  | Ground |
51 | TERMPWR |  | Termination Power |
52 | TERMPWR |  | Termination Power |
53 | res |  | reserved |
54 | GND |  | Ground |
55 | /ATN |  | Attention |
56 | GND |  | Ground |
57 | /BSY |  | Busy |
58 | /ACK |  | Acknowledge |
59 | /RST |  | Reset |
60 | /MSG |  | Message |
61 | /SEL |  | Select |
62 | /C/D |  | Control/Data |
63 | /REQ |  | Request |
64 | /I/O |  | Input/Output |
65 | DB8 |  | Data Bus 8 |
66 | DB9 |  | Data Bus 9 |
67 | DB10 |  | Data Bus 10 |
68 | DB11 |  | Data Bus 11 |
Note: Direction is Device relative Bus (other Devices) |  68 pin male connector at the cable |