 50 pin Amphenol female connector  at the controller & devices  | | Pin  | Name  | Dir  | Description |  
| 01 | GND |   | Ground |  
| 02 | +DB0 |   | +Data Bus 0 |  
| 03 | +DB1 |   | +Data Bus 1 |  
| 04 | +DB2 |   | +Data Bus 2 |  
| 05 | +DB3 |   | +Data Bus 3 |  
| 06 | +DB4 |   | +Data Bus 4 |  
| 07 | +DB5 |   | +Data Bus 5 |  
| 08 | +DB6 |   | +Data Bus 6 |  
| 09 | +DB7 |   | +Data Bus 7 |  
| 10 | +DBP |   | +Data Bus Parity (odd Parity) |  
| 11 | DIFFSENS | ? | ??? |  
| 12 | res | - | Reserved |  
| 13 | TERMPWR |   | Termination Power |  
| 14 | res | - | Reserved |  
| 15 | +ATN |   | +Attention |  
| 16 | GND |   | Ground |  
| 17 | +BSY |   | +Bus is busy |  
| 18 | +ACK |   | +Acknowledge |  
| 19 | +RST |   | +Reset |  
| 20 | +MSG |   | +Message |  
| 21 | +SEL |   | +Select |  
| 22 | +C/D |   | +Control or Data |  
| 23 | +REQ |   | +Request |  
| 24 | +I/O |   | +In/Out |  
| 25 | GND |   | Ground |  
| 26 | GND |   | Ground |  
| 27 | -DB0 |   | -Data Bus 0 |  
| 28 | -DB1 |   | -Data Bus 1 |  
| 29 | -DB2 |   | -Data Bus 2 |  
| 30 | -DB3 |   | -Data Bus 3 |  
| 31 | -DB4 |   | -Data Bus 4 |  
| 32 | -DB5 |   | -Data Bus 5 |  
| 33 | -DB6 |   | -Data Bus 6 |  
| 34 | -DB7 |   | -Data Bus Parity7 |  
| 35 | -DBP |   | -Data Bus Parity (odd Parity) |  
| 36 | GND |   | Ground |  
| 37 | res | - | Reserved |  
| 38 | TERMPWR |   | Termination Power |  
| 39 | res | - | Reserved |  
| 40 | -ATN |   | -Attention |  
| 41 | GND |   | Ground |  
| 42 | -BSY |   | -Bus is busy |  
| 43 | -ACK |   | -Acknowledge |  
| 44 | -RST |   | -Reset |  
| 45 | -MSG |   | -Message |  
| 46 | -SEL |   | -Select |  
| 47 | -C/D |   | -Control or Data |  
| 48 | -REQ |   | -Request |  
| 49 | -I/O |   | -In/Out |  
| 50 | GND |   | Ground |  
  Note: Direction is Device relative Bus (other Devices)  |  50 pin Amphenol male connector  at the cable  |