 50 pin hi-density D-SUB female connector at the controller & devices | | Pin | Name | Dir | Description |
| 01 | GND |  | Ground |
| 02 | +DB0 |  | +Data Bus 0 |
| 03 | +DB1 |  | +Data Bus 1 |
| 04 | +DB2 |  | +Data Bus 2 |
| 05 | +DB3 |  | +Data Bus 3 |
| 06 | +DB4 |  | +Data Bus 4 |
| 07 | +DB5 |  | +Data Bus 5 |
| 08 | +DB6 |  | +Data Bus 6 |
| 09 | +DB7 |  | +Data Bus 7 |
| 10 | +DBP |  | +Data Bus Parity (odd Parity) |
| 11 | DIFFSENS | ? | ??? |
| 12 | res | - | Reserved |
| 13 | TERMPWR |  | Termination Power |
| 14 | res | - | Reserved |
| 15 | +ATN |  | +Attention |
| 16 | GND |  | Ground |
| 17 | +BSY |  | +Bus is busy |
| 18 | +ACK |  | +Acknowledge |
| 19 | +RST |  | +Reset |
| 20 | +MSG |  | +Message |
| 21 | +SEL |  | +Select |
| 22 | +C/D |  | +Control or Data |
| 23 | +REQ |  | +Request |
| 24 | +I/O |  | +In/Out |
| 25 | GND |  | Ground |
| 26 | GND |  | Ground |
| 27 | -DB0 |  | -Data Bus 0 |
| 28 | -DB1 |  | -Data Bus 1 |
| 29 | -DB2 |  | -Data Bus 2 |
| 30 | -DB3 |  | -Data Bus 3 |
| 31 | -DB4 |  | -Data Bus 4 |
| 32 | -DB5 |  | -Data Bus 5 |
| 33 | -DB6 |  | -Data Bus 6 |
| 34 | -DB7 |  | -Data Bus Parity7 |
| 35 | -DBP |  | -Data Bus Parity (odd Parity) |
| 36 | GND |  | Ground |
| 37 | res | - | Reserved |
| 38 | TERMPWR |  | Termination Power |
| 39 | res | - | Reserved |
| 40 | -ATN |  | -Attention |
| 41 | GND |  | Ground |
| 42 | -BSY |  | -Bus is busy |
| 43 | -ACK |  | -Acknowledge |
| 44 | -RST |  | -Reset |
| 45 | -MSG |  | -Message |
| 46 | -SEL |  | -Select |
| 47 | -C/D |  | -Control or Data |
| 48 | -REQ |  | -Request |
| 49 | -I/O |  | -In/Out |
| 50 | GND |  | Ground |
Note: Direction is Device relative Bus (other Devices) |  50 pin hi-density D-SUB male connector at the cable |